Design-day capacity is table stakes. Buildings run at part load nearly all year — and that is where a high-performance specification is actually decided.
AHRI 920 rates a DOAS on ISMRE2, a seasonal efficiency that weights the hours a unit actually runs rather than the one afternoon it was selected for. Viking is engineered for that number: modulating compressors, a VFD supply fan and modulating hot-gas reheat hold a supply dewpoint as low as 43°F whether the ambient is 95°F or 65°F, without overcooling the space to get there.
That matters because ASHRAE 90.1 and the IECC now set minimum ISMRE2 values for DX-DOAS equipment. A unit that only performs at design conditions can fail the energy code at part load; Viking is selected against the code margin, not the catalog peak. Every certified family is listed in the AHRI directory under ASHRAE SSPC 198 — the method of test KCC engineers helped write and still vice-chair.
The result is a unit that carries the latent load on its own, so the terminal equipment downstream is selected for sensible load only, sized smaller and sequenced simply. Application guides by market and the AHRI certificate for each model family are in the resource library.
Campus air management
Dewpoint control · Mission-critical
Precision dewpoint
Supply dewpoint, all ambients
Certified · ISMRE2 rated
Conditioned outdoor air
DX, chilled water, air- & water-source heat pump
Explore Viking DOAS models and capacities to find the right solution for your project's requirements.
| Model Family | Nominal Airflow | Cooling | Heat Option | AHRI 920 | Spec Sheet |
|---|---|---|---|---|---|
| Viking OAB3 – 9 tons | 500 – 3,000 CFM | DX · Chilled water | Gas · Electric · Hot water · Heat pump | Certified | Spec sheet → |
| Viking OAD10 – 30 tons | 1,200 – 8,000 CFM | DX · Chilled water | Gas · Electric · Hot water · Heat pump | Certified | Spec sheet → |
| Viking OAK30 – 60 tons | 3,000 – 13,500 CFM | DX · Chilled water | Gas · Electric · Hot water · Heat pump | Certified | Spec sheet → |
| Viking OAN40 – 80 tons | 4,000 – 20,000 CFM | DX · Chilled water | Gas · Electric · Hot water | Certified | Spec sheet → |
| Viking HA10 – 15 tons | 1,500 – 6,000 CFM | DX | Gas · Electric · Heat pump (ASHP) | — | Spec sheet → |
Pressurization and IAQ where dewpoint control is not optional.
Campus air management across mixed building vintages.
Precision dewpoint for process-critical environments.
Size and schedule the unit.
Families by model group.
Searchable, current, dated.
Editable CSI-format text.
No OEM layer, no offshore parent. Enter your territory and we'll connect you to the regional partner who covers it.